A Comprehensive Guide To The Apollo Manual Call Point XP95

Written by

in

The Apollo Manual Call Point XP95 is a crucial component of any fire detection and alarm system These call points are designed to be easily accessible in case of an emergency, allowing individuals to initiate a manual fire alarm signal quickly In this article, we will provide an in-depth guide to the Apollo Manual Call Point XP95, discussing its features, installation, and maintenance.

Features of the Apollo Manual Call Point XP95

The Apollo Manual Call Point XP95 is specifically designed for use with Apollo’s addressable XP95 fire detection and alarm system It is equipped with a dual-action operation, requiring the user to break the glass before pressing the resettable element to activate the alarm This dual-action feature helps prevent accidental activation of the alarm, ensuring that it is only used in emergency situations.

Additionally, the Apollo Manual Call Point XP95 is designed with a unique loop-powered technology, allowing it to communicate directly with the fire alarm control panel This means that the panel will immediately receive a signal when the call point is activated, providing rapid response to any potential fire hazards.

Installation of the Apollo Manual Call Point XP95

Installing the Apollo Manual Call Point XP95 is a relatively simple process that can be completed by a qualified technician The call point should be mounted on a suitable surface, such as a wall or pillar, at a height of approximately 1.4 to 1.7 meters above the floor This height ensures that the call point is easily accessible in case of an emergency.

Once the call point is securely mounted, the technician will need to connect it to the fire alarm control panel using the loop wiring provided The call point should be wired in accordance with the manufacturer’s instructions to ensure proper communication with the panel.

Maintenance of the Apollo Manual Call Point XP95

Regular maintenance of the Apollo Manual Call Point XP95 is essential to ensure its reliability in an emergency situation apollo manual call point xp95. It is recommended that the call point is visually inspected on a regular basis to check for any signs of damage or tampering The glass element should also be inspected to ensure that it is intact and has not been broken.

In addition to visual inspections, the call point should be tested regularly to ensure that it is functioning properly This can be done by inserting a test key into the resettable element and pressing it to activate the alarm If the alarm sounds and the panel receives a signal, the call point is working correctly.

It is important to note that only trained personnel should perform testing and maintenance on the Apollo Manual Call Point XP95 to ensure safety and compliance with regulations Any issues or malfunctions should be promptly reported to the appropriate authorities for further investigation and repair.

Conclusion

The Apollo Manual Call Point XP95 is a vital component of any fire detection and alarm system, providing a reliable means of initiating a manual fire alarm signal With its dual-action operation and loop-powered technology, this call point is designed to ensure rapid response to any potential fire hazards.

By following the guidelines outlined in this article, you can effectively install and maintain the Apollo Manual Call Point XP95 to help protect lives and property in the event of a fire emergency Remember to always consult the manufacturer’s instructions and seek professional assistance if needed to ensure proper installation and functionality of this crucial safety device